On 9/15/07 an unintentional fall of rock occurred on the 5th South Sub Mains off the 5th West Parallels in the #3 entry. The fall was approximately 60' long x 17' wide and 6' thick. The fall was bolted with 6' point anchor bolts. The fall will not be cleaned up. The fall was laminated stack rock.