The fall at #7 entry, #23 xc on the south ""B"" submain, continued on riding out the cribs set between the #6 & #7 entry. The fall went through the crosscut from #7 entry to #6 entry and continued to within 15 feet of the #5 entry. The fall was 18' wide, 70' long, 10' high. The area was bolted with 5' fully grouted resin bolts. No one was injured. No equipment was damaged or trapped.