Unintentional roof fall discovered. Location of fall is old North Mains No. 1 Section, 63 Block, 5 entry, station 473. Fall measured approximately 30'L X 18'W X 6'H. Previously supported with 6' full grout resin bolts. Mined on or about 10/13/2006. Overburden approximately 250'.