# HOISTING
> MSHA accident `220072670012` · 09/19/2007 · Peabody Midwest Mining, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peabody Energy Corporation
- **Operator:** Peabody Midwest Mining, LLC
- **Mine:** [1202010](https://api.ai-analytics.org/mine/1202010)
## Narrative

During an MSHA inspection of our emergency hoist, it was found that the hoist was not functioning properly.  The hoist would not release the brake to lower the hoist into the intake shaft.  The investigation revealed that the 90 VDC power supply had failed which powered the drum brake release circuit.  The power supply was replaced and the hoist was returned to service.

---