A roof fall was found at 7:10 AM by employee looking for water stoppage. Fall had broken water line. Fall was in four way intersection at cross-cut 172 main south, entry #2. Fall was approx. 10' high, 20' wide, 30' long. Area was mined January 1997, and supported with 8' full resin bolts. No injury resulted and fall will not be cleaned up.