A roof fall occurred in the 2nd South submain entry #3 at 2170 footage station. The fall was 20 ft long, 20 ft wide, & 8 ft tall. The area was bolted with 6' & 8' point anchor bolts. The fall did not affect ventilation, block travelway or cause injury. No one is required to travel or work in this entry.