On 10/04/07 an unintentional fall of roof occured on the 4th South Sub-Main, #5 entry, at cross cut number 31. The fall was 18' long x 18' wide x 10' high and was bolted with 10' point anchor roof bolts. The fall was caused by fractured laminated stack rock and will be cleaned up.