A ROOF FALL WAS DISCOVERED IN THE #3 ENTRY AT SPAD 917. THE AREA IS APPROXIMATELY 20' X 80' LONG X 10' HIGH. THE FALL WAS LOCATED IN THE NEUTRAL OUTBY THE WORKING SECTION. THE FALL DID NOT AFFECT PERSONS, EQUIPMENT NOR VENTILATION. IT HAS BEEN DANGERED AND CRIBBED OFF.