Unintentional roof fall discovered during examination. Fall measurfed approximately 50'Lx25'Wx10'H. Fall was located at No. 1 section, 11 entry, 17 block, station 4931. Area previously supported with 10' cable bolts and 6' full grout resin bolts. Area developed on or about 8-18-06.