← MSHA accidents

FALL OF ROOF OR BACK

220073030034 · 10/16/2007 · CONSOL of Kentucky Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
CONSOL of Kentucky Inc.
Mine
4608892

Narrative

An unintentional roof fall occurred in the #5 entry at spad #731. Size of fall was estimated to be 22'W x 22'L x 5-6'H. The area had been supported with 4' fully grouted resin bolts with additional support consisting of 2 cribbs. No injuries, ventilation was not interrupted, no equipment caught. Fall will not be cleaned up.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown