An unintentional roof fall occurred in the #5 entry at spad #731. Size of fall was estimated to be 22'W x 22'L x 5-6'H. The area had been supported with 4' fully grouted resin bolts with additional support consisting of 2 cribbs. No injuries, ventilation was not interrupted, no equipment caught. Fall will not be cleaned up.