An unintentional rock fall occured in the 1A panel at crosscut #46 between entries 7 and 8. The fall did not affect ventilation, passege of men or cause personal injury. The fall measured 25' x 18' x 41/2' high. It will not be cleaned up. It had been supported with 48"" fully grouted roof bolts.