Fall was found by the preshift examiner on the 3rd shift it was located two cross cuts inby survey station 12770 in the number five intersection catching the head of the continous miner. Fall is approx. 20'x20'x6' high it was investigated by MSHA and OMSL. Fall will not be cleaned at this time the section will be moved outby this bad area.