An unintentional fall of roof occured in #5 entry, cross cut #33, on the 4th South Sub Main. The fall measured 20' long x 18' wide x 15' thick. The fall consisted of fractured lamanated stack rock. The area was bolted with 10' point anchor bolts. The fall will be cleaned up and resupported.