# FALL OF ROOF OR BACK
> MSHA accident `220073370028` · 11/28/2007 · ICG Hazard, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG Hazard, LLC
- **Mine:** [1518991](https://api.ai-analytics.org/mine/1518991)
## Narrative

The mine experienced an unintentional roof fall outby the active section on the parallel leatherwood mains at crosscut #45. The fall is approximately 160' long & 5' to 6' thick. The roof in the area is layered shale. This area had been permanently supported with 4' fully grouted rods. The fall extended thru the intersection from #3 to #6 entries.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*