The roof fall was 40' long x 18' wide x 4-7' thick in the laminated slate roof. The fall was in the belt entry on #7 belt at spad #2602. The fall was cleaned up and re-bolted according to the Rehabilitation Plan. The fall was approximately 500' from the active section.