# FALL OF ROOF OR BACK
> MSHA accident `220073410049` · 12/06/2007 · ICG-Illinois, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG-Illinois, LLC
- **Mine:** [1102664](https://api.ai-analytics.org/mine/1102664)
## Narrative

A roof fall was found at 2:39 pm at cross cut #5 entry 3 main west. This four way intersection had been mined Jan 1998 & was bolted with 8' full resin pins. Fall was 20' long x 20' wide x 10' high. No injury or property damage resulted. This fall may have to be cleaned up at a future date. If so, MSHA will be notified. Fall was reported because it is adjacent to an escapeway.

---