On 12/07/2007 an unintentional fall of roof occurred on the 4th South Sub Main, entry #5, at cross cut #29. The fall was approximately 45' long x 18' wide x 15' thick. The area was bolted with 10' point anchor roof bolts and cribs. The fall was in the belt entry. The area was fractured stack rock.