An unintentional roof fall occurred on the East pillar section, in No. 1 entry, approx 30' inby survey station 11783. The fall extened from the second lift in the left hand barrier into the entry and fell on the No.3 and No.4 MRS's. The fall was approx 5' high, 10' wide and 20' long.