# FALL OF ROOF OR BACK
> MSHA accident `220073510061` · 12/06/2007 · Alex Energy Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Alex Energy Inc
- **Mine:** [4608787](https://api.ai-analytics.org/mine/4608787)
## Narrative

An unintentional roof fall occurred on the above date. The fall occurred on 3 belt, No. 2 entry, No 8 to 9 break inby spad 1258. The fall measured 125' length, 20' width, above anchor point. Fall is in the nuetral entry 3000' outby working face. No injured occurred from the fall.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*