A roof fall was discovered on this date. The fall was located in the #3 entry, #4 crosscut of 6-North. The fall measured approximately 20' x 30' x 12' in thickness. The fall did not affect production or ventilation. The area was previously supported with 5' hi-tech bolts and 8' super bolts. The area was cribbed and dangered off.