On 01/01/08 an unintentional roof fall occurred on the 3rd South Submain, #6 entry, at #5 cross cut. The fall measured approximately 18' wide x 50' long, and over 10' thick. The area was bolted with 10' point anchor bolts. The area will be cleaned up as per the roof control plan.