A roof fall was found during mine exam at cross cut 74 entry #4 5R MS. Fall was in a four way intersection that had been mined October 2004 and supported with 8' full resin pins. Fall was 40' long x 30' wide & 10' high. No injury or property damage resulted. There are no plans to clean this fall up.