An unintentional roof fall has occurred in the intersection of the South East Main Return, in # 7 entry, at 30+10 crosscut. The cause of the roof fall was laminated and unconsolidated shale at the anchorage point. The area had been supported with 6 foot fully grouted roof bolts.