A roof fall occurred in the #1 entry of the 3lem (mmu 002) section. The fall was approx. 40' in length x 18' wide x 6' high. The fall started 30' outby #50 intersection. The top was bolted with 5' resin bolts with wire mesh. The fall partially covered both lube truck #lt235 and fletcher roof bolt #rb002.