← MSHA accidents
FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
220080580046 · 02/20/2008 · Clean Energy Mining Co.
Details
Degree of injury DAYS AWAY FROM WORK ONLY
Classification FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
Accident type Struck by rolling or sliding object
Occupation Roof bolter, Rock bolter, Pinner, Mobile roof support operator (MRS)
Activity Roof bolter, NEC
Injury source CAVING ROCK,COAL,ORE,WSTE
Nature of injury CONTUSN,BRUISE,INTAC SKIN
Body part MULTIPLE PARTS (MORE THAN ONE MAJOR)
Days lost 65
Mine experience 2.33 years
Operator
Controller (parent) Massey Energy Company
Operator Clean Energy Mining Co.
Mine 1510753
Narrative EE was on operator side of RB, had put up first row of bolts, was moving machine up for next row. Rib rolled off, striking left shoulder and arm area. Taken to ER for treatment.