A roof fall was found by an examiner while examining outlying faces away from the working section. It was located at 5+15 #6 Entry of Zone Sub 2. The area was developed 1-27-08 & was abandoned 2-1-08. The fall was 20'L x 18'6"" W x 8'H. The area was originally supported w/6' fully grouted resin bolts. No injuries, air flow not disturbed, passage of men not affected.