A roof fall was found by an employee while driving on the haul road. The fall was located at 41 + 30 #4 entry of zone sub 1 on mmu-01. The area was developed 11/29/07. The fall was 25'L x 15'W x 8'H. The area was originally supported with 6' fully-grouted resin bolts. There were no injuries involved, air flow was not disturbed and the passage of men was not affected.