Fall loc.Entry No.6 Spad No.3 Brks. inby 1373;Dist. from active face 8500'; Airway:intake; Stopping line will be set over and life line reestab. Size: L55';W19';H3.5-4'; Roof sup.:Resin;No cribs or timbers installed prior to fall; Strata:mixed, lam.;NO coal rider seam; All entrance to fall brk. off; Area will be rehab.;Fall will be cleaned up when new miner and bolter is at face.