An unintentional roof fall outby on Unit 1 in Entry 7 between 5070 south and 5135 south. The fall was found by a mine examiner making his weekly inspection. The fall is approximately 25ft long, 18ft. wide, and 0-6ft. high. The fall will not be cleaned up. Fall area was supported with 5ft. conventional roof bolts.