At or around 3:00pm a roof fall occurred on the 004 section bleeder entry, just outby Spad No 23014. The fall measured 18 feet wide x 18 feet long x 8 feet high. No injuries were reported as a result of this fall of roof rock. The fall will not be cleaned and all entries leading to the roof fall have been timbered and danger signs installed.