A roof fall measuring 50' length, 20' wide, and 6' thick was discovered in the return entry 1500' outby the working face. The area was initially developed Nov 07 with 5' torque tension roof bolts used. The fall occurred due to shale mixed with coal streaks above the anchorage zone. Fall location was #6 entry 1st left panel.