A roof fall measuring 30' length, 20' wide, and 7' thick was discovered in the return entry 1500' outby the working face. The area was developed Nov 07 with 5' torque tension roof bolts. The fall occurred due to shale mixed with coal streaks above the anchorage zone. Fall location was in # 2 entry on 1st left panel near spad 58748.