An unintentional roof fall occurred on the #4 section in the #8 entry one x-cut inby spad #44917. The fall measured to be about 6' high, 20' wide and 60' long. The area was bolted with 5' torque tension bolts. The fall will not be cleaned up. All entrances were cribbed and dangered off.