An unplanned roof fall was discovered in the return air course in a room panel off 10 Right Main.This fall is located at spads #5241 and 5242. It is approximately 10 feet high and 60 feet long. The area was supported with 6 foot, fully grouted resin rods. The area was dangered off. The fall did not affect the ventilation at this mine.