# HOISTING
> MSHA accident `220081340031` · 05/10/2008 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

The hoist was descending the brakecar when the hoist shut down.  A 800 amp fuse blew, after replacing the fuses the breaker would not re-set (kept knocking). When the fuse blew it arced across the back of the Siemens electronic computer controls.  A new control box had to be replaced and programmed.  Cause of this was the arc shield was found to be missing.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*