The mine encountered a fall of roof on the 1st MS, entry #4, S.S. 21+10. The fall measured 50'L X 18.5'W X 12' thick. The area was developed on 12/31/07. The fall did not affect ventilation or passage of men, no personal injuries or equipment damage. The area was supported with 8' point anchor bolts. This fall will not be cleaned up.