An unintentional roof fall has occurred between the #3 & #2 entries at 27+60 on the 2 mw in the return. The fall was discovered on the weekly exam. The fall was approximately 20' long and 7.5' high and approximately 16.5' wide. The intersection #3 had been cribbed prior to fall, from the intersection of #3 to the #4 entry.