# FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
> MSHA accident `220081490026` · 05/20/2008 · Long Branch Energy
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
- **Accident type:** Struck by... NEC
- **Occupation:** Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)
- **Activity:** Roof bolter, Drilling
- **Injury source:** DRILL STEEL (ALL SIZES)
- **Nature of injury:** CONTUSN,BRUISE,INTAC SKIN
- **Body part:** TRUNK, MULTIPLE PARTS
- **Days lost:** 138
- **Mine experience:** 1.17 years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4604955](https://api.ai-analytics.org/mine/4604955)
## Narrative

Employee was installing rib bolts. When removing steel the rib rolled, striking steel causing steel to strike left shoulder  and ribs.

---