While traveling airways in the old 5Lt. Section with an MSHA inspector a roof fall was discovered at spad #8016 in #3 entry. The fall measured 20'L X 20'W X 4' high. The area was supported with 4' resin bolts. The area has been dangered off and timbers have been set. The area was mined approx. 4/07.