# FALL OF ROOF OR BACK
> MSHA accident `220081580033` · 06/04/2008 · West Virginia Mine Power, Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** John B  Preece
- **Operator:** West Virginia Mine Power, Inc
- **Mine:** [4609154](https://api.ai-analytics.org/mine/4609154)
## Narrative

During normal mine travel a roof fall was discovered at spad #382. The fall measured app. 19' wide X 25' long X 5' high. 4 foot fully grouted bolts were used during mining on 4/16/07. The fall is in the intake app. 5000' from the face. The mine is non-producing. All sides of the fall have been timbered off. Will not be cleaned.

---