A roof fall has occured in the 1st South Main Entrys at 16+80 in #2 entry.fall measures approximately 50' x 20' x 6' and was caused by an undetected slip in the mine roof.Area was supported by 6' tension rebar roof bolts and was mined in July 2007.There were no injuries and ventilation/passage of men were not affected.