# ELECTRICAL
> **FATAL** · MSHA accident `220081700037` · 05/16/2008 · Aracoma Coal Company, LLC
## Details
- **Degree of injury:** FATALITY
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Electrician, Lineman
- **Activity:** Electrical maintenance
- **Injury source:** CONDCTR,ELCT,CBL,TROL POL
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 0
- **Mine experience:** 0.37 years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Aracoma Coal Company, LLC
- **Mine:** [4608801](https://api.ai-analytics.org/mine/4608801)
## Narrative

While atempting to repair a shuttle car without determining that the trailing cable was de-energized and without locking-out and tagging the power source. EE received fatal injries when he cut into an energized phase lead.

---