The mine encountered a roof fall on the 1st MS, entry #3, S.S. 00+80. The fall measured 30'L X 19'W X 8' thick. The area was developed on 5/10/2007. The fall did not affect ventilation or passage of men, no personnal injuries or equipment damage. The fall was supported with 8"" point anchor bolts. This fall will not be cleaned up.