← MSHA accidents

FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL

220081840024 · 06/27/2008 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4601318

Narrative

The rib over the inby overcast wall located along 6 North belt at 71 block deteriorated and fell out breaching the separation of the air-courses. Fallen material measured 5 ft by 4 ft by 14 ft. No injuries to any employees.

Source

Authoritative
MSHA Open Government Data
Machine