The mine encountered an unintentional roof fall on the Main South, entry #4, at the 3+60 intersection. The fall measured 60' X 18' X 8' thick. It did not affect ventilation or the passage of men, no personal injuries. The area was developed on 6/16/07, supported with 8' point anchor bolts. This fall will not be cleaned up.