Roof fall measuring 20 ft X 19 ft X 5 ft 7 in occurred outby #1 entry at spad #17305. There was no equip involved, in the return airway, ventiltion was not affected, passage of persons was affected. Area was breakered off, and will be rehabilitated. Both MSHA and state agency was notified.