# FALL OF ROOF OR BACK
> MSHA accident `220082050032` · 07/22/2008 ·  Clean Energy Mining Co.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:**  Clean Energy Mining Co.
- **Mine:** [1510753](https://api.ai-analytics.org/mine/1510753)
## Narrative

Roof fall measuring 28 ft X 20 ft X 6 ft occurred in #3 entry intake at spad #19535.  Area was not breakered off, and will not be rehabilitated.  We will crib and danger off the entries to the fall, clean, spot bolt, and re-route the intake.  Both MSHA and state agencies were notified.

---