A roof fall was found on 7/28/08 at 6:20 am by an examiner inspecting a set of seals. The fall which measured 8' high x 20' wide, and 40' long was in a four way intersection at 40+60 entry 0 in 5rms. Area had been mined 3/2003 and was supported with 8' full resin bolts. no injury resulted and fall will not be cleaned up. Fall was reported because it was adjacent to examiner