A roof fall was discovered at 14x 3 main #5 & 5+4 intersection into x cut toward #4. Fell above anchorage. 6' fully grouted resin bolts + 4 12' cable bolts were in use. No men or machines injured or trapped. No ventilation or travel was affected. 4,000 outby face.