← MSHA accidents
ELECTRICAL
220082320002 · 07/31/2008 · Heidtman Mining LLC
Details
Degree of injury DYS AWY FRM WRK & RESTRCTD ACT
Classification ELECTRICAL
Accident type Contact with electrical current
Occupation Roof bolter, Rock bolter, Pinner, Mobile roof support operator (MRS)
Activity Move power cable
Injury source CONDCTR,ELCT,CBL,TROL POL
Nature of injury ELECTRIC BURN-CNTACT BURN
Body part ARM, MULTIPLE PARTS
Days lost 9
Mine experience 1.71 years
Operator
Controller (parent) R Alex Johnson
Operator Heidtman Mining LLC
Mine 0301736
Narrative Roof bolter cable was smashed under the bolter. When employee was trying to remove it, the breaker was accidentally reset, causing an electrical burn to the employees arm.