← MSHA accidents

ELECTRICAL

220082320002 · 07/31/2008 · Heidtman Mining LLC

Details

Degree of injury
DYS AWY FRM WRK & RESTRCTD ACT
Classification
ELECTRICAL
Accident type
Contact with electrical current
Occupation
Roof bolter, Rock bolter, Pinner, Mobile roof support operator (MRS)
Activity
Move power cable
Injury source
CONDCTR,ELCT,CBL,TROL POL
Nature of injury
ELECTRIC BURN-CNTACT BURN
Body part
ARM, MULTIPLE PARTS
Days lost
9
Mine experience
1.71 years

Operator

Controller (parent)
R Alex Johnson
Operator
Heidtman Mining LLC
Mine
0301736

Narrative

Roof bolter cable was smashed under the bolter. When employee was trying to remove it, the breaker was accidentally reset, causing an electrical burn to the employees arm.

Source

Authoritative
MSHA Open Government Data